Link 400 Internal Antennas
CurrentRugged multi-WAN data bonding appliance combining cellular, satellite, and wired networks for resilient field connectivity Raw value as published“Rugged multi-WAN data bonding appliance combining cellular, satellite, and wired networks for resilient field connectivity” SourceTeradek product data Tier: Lab estimateObserved 2026-10-21Confidence: medium Method: humanReview: draft1 alternative claimOverrides the official claim Greyed: “Official only” is on. Not counted in completeness.
Power
| Field | Value | Last checked |
|---|---|---|
| Lowest input voltage |
12 V
Raw value as published“12”
SourceTeradek product data
Tier: Lab estimateObserved 2026-10-21Confidence: medium
Method: humanReview: draft1 alternative claimOverrides the official claim
Greyed: “Official only” is on. Not counted in completeness.
Published figures disagree: 12 V (Teradek product data) and 24 V (official page at teradek.com, seen 2026-10-21); shown: 12 V. |
2026-10-21 |
| Highest input voltage |
30 V
Raw value as published“30”
SourceTeradek product data
Tier: Lab estimateObserved 2026-10-21Confidence: medium
Method: humanReview: draft1 alternative claimOverrides the official claim
Greyed: “Official only” is on. Not counted in completeness.
Published figures disagree: 30 V (Teradek product data) and 24 V (official page at teradek.com, seen 2026-10-21); shown: 30 V. |
2026-10-21 |
| Typical power draw |
20 W
Raw value as published“20”
SourceTeradek product data
Tier: Lab estimateObserved 2026-10-21Confidence: medium
Method: humanReview: draftCorroborated by 1 sourceOverrides the official claim
Greyed: “Official only” is on. Not counted in completeness.
|
2026-10-21 |
| Maximum power draw |
36 W
Raw value as published“36”
SourceTeradek product data
Tier: Lab estimateObserved 2026-10-21Confidence: medium
Method: humanReview: draftCorroborated by 1 sourceOverrides the official claim
Greyed: “Official only” is on. Not counted in completeness.
|
2026-10-21 |
| Battery mounts |
none
Raw value as published“none”
SourceTeradek product data
Tier: Lab estimateObserved 2026-10-21Confidence: medium
Method: humanReview: draftOverrides the official claim
Greyed: “Official only” is on. Not counted in completeness.
|
2026-10-21 |
| Connector |
2-pin circular locking connector (24V DC power); 2-pin circular locking connector (12V-30V battery input)
Raw value as published“2-pin circular locking connector (24V DC power); 2-pin circular locking connector (12V-30V battery input)”
SourceTeradek product data
Tier: Lab estimateObserved 2026-10-21Confidence: medium
Method: humanReview: draft1 alternative claimOverrides the official claim
Greyed: “Official only” is on. Not counted in completeness.
|
2026-10-21 |
Battery runtime
50 Wh: about 2.5 h at typical draw (20 W), about 1.4 h at maximum draw (36 W)
98 Wh: about 4.9 h at typical draw (20 W), about 2.7 h at maximum draw (36 W)
150 Wh: about 7.5 h at typical draw (20 W), about 4.2 h at maximum draw (36 W)
Runtime = battery watt-hours ÷ stated draw: an estimate, not a measured runtime. Not included: the monitor, camera and accessories on the same battery, conversion losses, battery ageing and cold.
Not on this site